EngmBuild #1129: 2026-11-02 13:58:25 ···Rendr: measuring…·dbquar: 0·Disk: measuring…·FCP: measuring…·LCP: measuring…·Load: measuring…·Reqs: measuring…·Cache%: measuring…·Weight: measuring…

Door Hub

Door Hub

35 600 ₽ · В наличии · Артикул: UA-Hub-Door

Механизм для одной двери, обеспечивающий полный контроль входа и выхода с помощью подключенных считывателей доступа.

Характеристики

ТипКонтроллер
Uplink1
Dimensions174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
Weight363 g (12.8 oz)
Enclosure MaterialPolycarbonate
MountingDIN-rail (Included)
Ambient Operating Temperature0 to 40° C (32 to 104° F)
Ambient Operating Humidity5 to 95% noncondensing
NDAA Compliant✓
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Maximum User Count6
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Mount MaterialPolycarbonate
Indoor and Outdoor UseIndoor only
Networking Interface(5) 10/100/1000 Base-T
Power MethodPoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Max. Power Consumption30W (Without PoE output) 50W (With PoE output)
Powered Output RelayLock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A
LEDsW/B Learn More
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: 1
Document number, and issue date and/or revision levelUA-Hub-Door002, V01
Management ApplicationAccess
Software InformationThe software version can be checked at https://unifi.ui.com
Supported Doors1
Input Terminals(2) Door exit request (1) Door position (1) Emergency
PoE Interface(1) PoE++ input, 50V DC, 1A (4) PoE+ outputs, 50V DC, 30W per port (Max 45W aggregated)
Digital InputRequest to exit, request to enter, remote release, door position sensor
Dry Output RelayLock: 30V DC, 1A Aux: 30V DC, 1A
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
Buttons(1) Factory reset