EngmBuild #1129: 2026-11-02 13:58:25 ···Rendr: measuring…·dbquar: 0·Disk: measuring…·FCP: measuring…·LCP: measuring…·Load: measuring…·Reqs: measuring…·Cache%: measuring…·Weight: measuring…

G2 Starter Kit

G2 Starter Kit

48 100 ₽ · В наличии · Артикул: UA-G2-SK

Простой комплект «всё в одном» для UniFi Access, предназначенный для управления одной дверью с одним считывателем. Обеспечивает быструю настройку современной и безопасной системы контроля доступа.

Характеристики

ТипКомплект
Uplink1
Dimensions85.6 x 53.98 x 0.84 mm (3.37 x 2.13 x 0.03")
Weight5 g (0.18 oz)
Enclosure MaterialPolycarbonate, glass
MountingIn-wall, gang box (Included) Junction box (Optional)
Ambient Operating Temperature-30 to 45° C (-22 to 113° F)
Ambient Operating Humidity5 to 90% noncondensing
NDAA Compliant✓
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
NFC Card & Keyfob Access✓
Mobile Unlock✓
WeatherproofingIP55
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Mount MaterialAluminum alloy
Indoor and Outdoor Use✓
Networking Interface(1) 10/100 MbE RJ45 port
ConnectivityBLE 4.1 NFC
Power MethodPoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
Max. Power Consumption5W
Supported Voltage Range48V DC
ESD/EMP ProtectionAir: ± 15kV, contact: ± 8kV
Powered Output RelayLock: 12V DC, 1A Aux: 12V DC, 0.33A 12V DC, 0.33A
Speaker(1) Yes, 0.7W
LEDsR/G/B/W Learn More
Button(1) Factory reset
NFC Frequency13.56 MHz
NFC Read Range< 30 mm (1.18'')
NFC TechnologyISO/IEC 14443 Type A MIFARE DESFire UniFi Access Proprietary Security Protocol
PoE Cabling RequirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: I
Document number, and issue date and/or revision levelUA-G2/UA-G2-Black, V02
Management ApplicationUniFi Access
Software InformationThe software version can be checked at https://unifi.ui.com
In the Box(1) Door Hub (1) G2 Reader (10) Access Cards
Supported Doors1
Input Terminals(2) Door exit request (1) Door position (1) Emergency
PoE Interface(1) PoE++ input, 50V DC, 1A (4) PoE outputs, 50V DC, 30W per port (Max 45W aggregated)
Digital InputRequest to exit, request to enter, remote release, door position sensor
Dry Output RelayLock: 30V DC, 1A Aux: 30V DC, 1A
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
SensorsProximity sensor
Handwave Request to Exit✓
FormatISO 7810 ID-1