Retrofit Hub

41 100 ₽ · В наличии · Артикул: UA-Retrofit-Hub-2
Концентратор с питанием от постоянного тока, поддерживающий считыватели Wiegand и OSDP и обеспечивающий контроль входа и выхода для максимум двух дверей.
Характеристики
| Тип | Контроллер |
|---|---|
| Uplink | 0,1 |
| Dimensions | 140 x 120 x 45 mm (5.5 x 4.7 x 1.8") |
| Weight | 420 g (14.8 oz) |
| Enclosure Material | Polycarbonate |
| Mounting | Din-rail (Included) |
| Ambient Operating Temperature | -10 to 40° C (14 to 104° F) |
| Ambient Operating Humidity | 5 to 90% noncondensing |
| NDAA Compliant | ✓ |
| Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
| Maximum User Count | 10 |
| UL 294 Level | Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I |
| Mount Material | SGCC steel |
| Indoor and Outdoor Use | Indoor only |
| Networking Interface | (2) 10/100 MbE RJ45 ports |
| Power Method | 12/24V DC |
| Max. Power Consumption | 50W |
| Powered Output Relay | 12V Lock: 12V DC, up to 1A 24V Lock: 24V DC, up to 0.5A |
| LEDs | W/B Learn More |
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
| CAN/ULC-60839-11-1 Grade | Grade assignment: I |
| Document number, and issue date and/or revision level | UA-Retrofit-Hub-2, V01 |
| Management Application | Access |
| Software Information | The software version can be checked at https://unifi.ui.com |
| Power Supply | DC 12/24V |
| Supported Doors | 2 |
| Input Terminals | (2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency |
| Digital Input | (2) Third-party Wiegand Reader / UniFi Retrofit Reader (2) Door exit request (2) Door position (1) Emergency |
| Dry Output Relay | Lock: rated 30V DC, up to 1A Aux: rated 30V DC, up to 1A |
| UA-Lock-Electric (400mA) | 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft) |
| UA-Lock-Magnetic-540kg (500mA) | 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft) |
| UA-Lock-Magnetic-270kg (800mA) | 24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft) |
| Other locks (1A) | 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft) |
| Buttons | (1) Factory reset (2) 12V/Dry/24V switch |
| Reader Power Output | 12V DC, up to 0.5A |
| UA-Retrofit-Reader (250mA) | 18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft) |
No products match your search.