EngmBuild #1129: 2026-11-02 13:58:25 ···Rendr: measuring…·dbquar: 0·Disk: measuring…·FCP: measuring…·LCP: measuring…·Load: measuring…·Reqs: measuring…·Cache%: measuring…·Weight: measuring…

Enterprise Access Hub

Enterprise Access Hub

179 300 ₽ · В наличии · Артикул: EAH-8

Корпоративный хаб контроля доступа с контролем входа и выхода до восьми дверей и поддержкой резервного питания от аккумулятора.

Характеристики

ТипКонтроллер
Uplink1
Dimensions379 x 355 x 105 mm (15 x 14 x 4.1")
WeightDevice: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Enclosure MaterialSGCC steel housing with polycarbonate cover
MountingWall
Ambient Operating Temperature0 to 40° C (32 to 104° F)
Ambient Operating Humidity5 to 95% noncondensing
NDAA Compliant✓
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Maximum User Count10
UL 294 LevelDestructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Mount MaterialSGCC steel
Indoor and Outdoor UseIndoor only
Networking Interface(10) 10/100/1000 Base-T
Power MethodUniversal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
Max. Power Consumption240W
Powered Output RelayLock: 12V DC, 1A/ Dry Aux: Dry only
LEDsW/B Learn More
PoE Cabling RequirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 StatementCompliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: I
Document number, and issue date and/or revision levelEAH-8, Ver 01
Management ApplicationAccess
Software InformationThe software version can be checked at https://unifi.ui.com
Power SupplyAC/DC, internal
Supported Doors8
Input Terminals(8) Door exit request (8) Door position (1) Emergency
PoE Interface(8) PoE+ outputs, 50V DC, 30W per port (Max 190W aggregated)
Digital Input(8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dry Output Relay(8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
UA-Lock-Electric (400mA)24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
Buttons(1) Factory reset
Max. PoE Wattage per Port30W