EngmBuild #1129: 2026-11-02 13:58:25 ···Rendr: measuring…·dbquar: 0·Disk: measuring…·FCP: measuring…·LCP: measuring…·Load: measuring…·Reqs: measuring…·Cache%: measuring…·Weight: measuring…

UPS 2U Pro

UPS 2U Pro

121 900 ₽ · В наличии · Артикул: UPS-2U-Pro

Стоечный ИБП 1,92 кВА с управлением UniFi, чистым синусоидальным выходом, 8 индивидуально управляемыми розетками с мониторингом мощности по каждому порту и удалённым перезапуском питания, заменяемой на месте батареей 720 Вт·ч и автономной работой до 22 минут при половинной нагрузке 960 Вт.

Характеристики

Тип товараИБП
Форм-факторRack mount (2U)
Ambient Operating Humidity0 to 95% noncondensing
Networking Interface(1) 100/10 MbE port for network connection (2) GbE ports for surge in/out
Capacity1920VA/1920W
Температура хранения-15 to 50° C (5 to 122° F)
Power Method(1) TN system, 120V AC, 16A Max., 50/60 Hz
TypeLine interactive
WeatherproofingIP20
Вес32 kg (70.5 lb)
Buttons(1) Power (1) Factory reset (1) Circuit breaker
Input Voltage Range89–145V AC
Output Voltage120V AC
Operating EnvironmentPollution Degree 2
ManagementEthernet
Frequency RangeAC mode: 50/60 Hz ±5 Hz (Auto sensing) Battery mode: 60 Hz ±1 Hz
Габариты442.4 x 87.4 x 630 mm (17.4 x 3.4 x 24.8")
Материал корпусаGalvanized steel
СертификатыFCC, IC, UL 1778, CSA C22.2 No. 107.3
Display3.7” touchscreen
Mobile AppsiOS™: Version 10.36.1 and later Android™: Version 10.39.3 and later
UniFi NetworkVersion 10.5.67 and later
Power(1) OVC II AC in: NEMA 5‑20P (8) Battery backup/surge protection: NEMA 5‑20R
Nominal Input Voltage120V AC
AC Voltage Regulation±1.5% (Battery mode)
Transfer Time6 ms typical; 10 ms max. (Battery mode)
Wave FormPure sine wave (Battery mode)
Battery Type(1) Lead Acid 72V, 10Ah
RuntimeFull load: 9 min Half load: 22 min
Battery Charging Time8 hours recovery to 90% capacity
Overload at On-Line Mode103–120% 5 min go to fault 120–150% 10 sec go to fault 150% 1 sec go to fault
Overload at Battery Mode103–120% 1 min go to fault 120–150% 10 sec go to fault 150% 0.5 sec go to fault
Short Circuit Protection at On-Line ModeBreaker, 250V AC, 20A
StatusOff: device not turned on Flashing white: initializing / factory default Steady white: waiting for adoption Steady blue: device adoption and working Flashing blue: battery mode Alternating white/blue: firmware upgrading Rapid flashing blue: locate Steady red: warning Flashing red: low battery
Operating Altitude3,000 m (1.9 mi)
Nominal Output Voltage120V AC
Рабочая температу0 to 40° C (32 to 104° F)